Nyob rau hauv cov tsev kho mob niaj hnub no 'interventional departments, ultrasound departments los yog endoscopy chaw zov me nyuam, kev kuaj mob zoo thiab kev kho mob cia siab rau cov khoom siv sib koom ua ke. Ib qho khoom siv tshiab tau qhia, yog tias nws tsis tuaj yeem sib txuas nrog cov "ecosystem uas twb muaj lawm", nws qhov kev ua tau zoo siab yuav raug txo kom tsawg, thiab tej zaum nws yuav raug tso tseg vim kev ua haujlwm nyuaj thiab kev hloov pauv nyuaj. AccuSteel™ cannula hais txog nws kev sib raug zoo nrog INRAD coaxial introducers thiab mainstream biopsy systems, thiab Quick-Core biopsy koob muaj ntau yam programmable firing hom. Qhov no qhia txog qhov "system xav" thiab "workflow optimization" lub tswv yim. Lawv tsis yog cov cuab yeej ywj pheej nkaus xwb tab sis kuj yog cov kev daws teeb meem tsim los koom ua ke thiab txhim kho txoj hauv kev kho mob uas twb muaj lawm.
Tus nqi ntawm coaxial technology: Tsim kom muaj kev nyab xeeb thiab ua haujlwm zoo "ua haujlwm channel". Coaxial biopsy systems (xws li cov khoom INRAD) yog cov txheej txheem tseem ceeb hauv percutaneous biopsy. Cov tub ntxhais nyob rau hauv thawj zaug siv ib tug kuj tuab daim ntawv qhia koob (cannula) rau puncture rau ntawm ntug ntawm lub hom phiaj qhov txhab, tsim kom muaj ib tug ruaj khov channel, thiab tom qab ntawd los ntawm cov channel no, ntau yam thinner biopsy koob raug xa mus rau hauv cov qauv. Raws li ib feem ntawm coaxial system, tus nqi ntawm AccuSteel ™ cannula nyob rau hauv:
1. Txo cov ntaub so ntswg puas thiab mob: Tsuas yog ib daim tawv nqaij puncture yog xav tau rau ntau yam sampling, tsis txhob raug mob thiab mob tshwm sim los ntawm rov punctures ntawm daim tawv nqaij thiab cov ntaub so ntswg.
2. Precise positioning and path fixation: Thaum lub cannula muab tso rau hauv txoj hauj lwm, nws qhov chaw yog tsau nyob rau hauv cov duab saib xyuas. Cov koob txhaj tshuaj biopsy tom qab txhua tus nkag mus rau tib txoj hauv kev, kom ntseeg tau tias txhua qhov kev coj ua tau tsom mus rau tib cheeb tsam thiab txhim kho cov neeg sawv cev ntawm cov qauv.
3. Txo qhov kev pheej hmoo ntawm cov noob qoob loo: Txoj kev xav, lub cannula kaw cov koob kab, uas yuav txo tau txoj kev pheej hmoo ntawm cov qog hlwb tawm thiab cov noob nyob rau hauv txoj kab.
4. Txhim khu kev ua haujlwm zoo: Cov kws kho mob tuaj yeem hloov cov koob tshuaj biopsy sai sai yam tsis muaj qhov rov ua haujlwm dua, ua rau lub sijhawm ua haujlwm luv luv.
Yog li ntawd, kev sib raug zoo ntawm AccuSteel ™ nrog cov txheej txheem coaxial qhia tau hais tias cov tsev kho mob tsis tas yuav hloov tag nrho cov kev taw qhia kim heev los txhim kho lawv cov qauv piv txwv, ua rau lawv ua tiav kev txhim kho ntawm tus nqi qis.
Seamless kev koom ua ke nrog mainstream biopsy systems. Muaj ntau yam tsis siv neeg lossis ib nrab - tsis siv neeg biopsy rab phom ntawm kev ua lag luam, xws li Bard Magnum thiab Bard Maxcore. Txhua yam ntawm cov tshuab no muaj nws tus kheej mechanical interfaces thiab cov yam ntxwv ua haujlwm. Yog tias rab koob biopsy tsuas tuaj yeem hloov mus rau ib hom phom tshwj xeeb, nws yuav txwv nws cov ntawv thov ntau yam. Tus qauv tsim ntawm AccuSteel™ cannulas thiab Quick-Cov koob txhaj tshuaj tseem ceeb ua raws li cov qauv kev lag luam dav dav (xws li Luer lock interface thiab tus qauv snap- haum qhov ntev), kom ntseeg tau tias lawv tuaj yeem siv tau yooj yim thiab siv ncaj qha nrog feem ntau cov phom biopsy. Qhov no "platform kev ywj pheej" muab cov kws kho mob nrog qhov yooj yim tshaj plaws, tso cai rau lawv xaiv cov phom biopsy yooj yim tshaj plaws raws li cov yam ntxwv ntawm qhov txhab thiab tus cwj pwm ntawm tus kheej, thaum txaus siab rau cov txiaj ntsig ntawm cov cuab yeej siv thev naus laus zis tshiab thiab rab koob.
Ceev-Core's ntse firing hom: Kho kom haum rau cov xwm txheej nyuaj thiab ntau yam kev kho mob. Qhov ceev-Core biopsy koob muaj peb hom kev tua hluav taws xob - tsis siv neeg, qeeb, thiab xoom- pov - teeb tsa tus qauv tshiab rau kev ua haujlwm kom zoo.
- Hom Tsis Siv Neeg ('A'): Qhov no yog hom siv ntau tshaj plaws. Thaum tshwm sim, lub koob txhaj tshuaj thiab cov txiav cannula ua ib txhij kom ua tiav cov qauv sai. Nws yog haum rau feem ntau cov kab mob thiab yog ib qho yooj yim thiab ceev rau kev khiav lag luam.
- Delayed Mode ('D'): Hauv hom no, tsuas yog rab koob txhaj tshuaj (kab koob) tso tawm kom nkag mus rau lub hom phiaj pib. Tus kws kho mob tuaj yeem rov hais dua nyob rau hauv ultrasound tias lub koob taub yog nyob rau hauv qhov zoo tshaj plaws txoj hauj lwm ntawm qhov txhab ua ntej manually triggering lub txiav cannula kom tiav cov sampling. Qhov no "ob-kauj ruam kev lees paub" txheej txheem no ua rau muaj txiaj ntsig zoo thiab kev nyab xeeb ntawm kev sib tsoo, ua rau nws tsim tshwj xeeb rau thaj chaw txaus ntshai nyob ze rau cov hlab ntsha loj, cov ducts, los yog cov hlab ntsha hauv plab, lossis rau kev ua rau me me thiab mob hnyav heev (xws li cov qog ntshav ntawm lub plawv).
- Zero Needle Ejection Mode: Hauv hom no, lub tshuab hluav taws xob tsis eject lub koob lub cev rau pem hauv ntej. Nws tso cai rau tus kws kho mob kom tswj tau qhov tob thiab ceev ntawm rab koob txhaj tshuaj thiab txiav, ib yam li siv rab koob txhaj tshuaj. Qhov no muab kev tswj hwm tsis sib xws thaum cuam tshuam nrog cov kab mob loj heev lossis palpable thiab tseem tsim nyog rau kev qhia thiab kev cob qhia cov xwm txheej.
Los ntawm "instrument operation" mus rau "lesion-centered" txheej txheem reengineering. Cov qib siab ntawm kev sib raug zoo thiab kev teeb tsa tau kawg tau hloov qhov kev tsom mus rau kev ua haujlwm kho mob. Yav dhau los, cov kws kho mob yuav tsum tau siv ntau qhov kev siv zog ua kom haum rau "temperaments" ntawm cov twj sib txawv lossis kev cuam tshuam rau cov phiaj xwm phais vim muaj kev txwv cov cuab yeej. Tam sim no, cov kws kho mob tuaj yeem:
1. Kev Npaj Ua Ntej: Raws li cov duab ua ntej, hom kev taw qhia (coaxial lossis tsis yog-coaxial) yuav tsum siv, hom koob taub (Mitsubishi rau cov ntaub so ntswg tawv, ob chav bevel rau niaj hnub), thiab hom emission (tsis siv neeg rau thaj chaw nyab xeeb, ncua sij hawm rau thaj chaw txaus ntshai) yog tag nrho ua ntej -planned.
2. Ua kom pom tseeb ntawm Lub Hom Phiaj: Thaum lub sijhawm ua haujlwm, tus kws kho mob tuaj yeem ua kom pom tseeb ntawm daim duab ultrasound, tsom rau kev txheeb xyuas qhov mob, tsis txhob muaj cov hlab ntsha, thiab xaiv qhov zoo tshaj plaws sampling point, tsis muaj kev cuam tshuam los ntawm kev hloov kho ntawm cov cuab yeej lossis kev hloov pauv ntawm kev ua haujlwm cumbersome.
3. Dynamic Adjustment: Yog tias qhov kev kuaj thawj zaug tsis txaus siab, lub koob tshuaj biopsy ntawm tus qauv sib txawv lossis cov lus qhia tuaj yeem hloov pauv sai sai los ntawm coaxial channel rau lwm qhov kev sim. Tag nrho cov txheej txheem yog du thiab muaj txiaj ntsig.
Cov txiaj ntsig kev lag luam thiab kev cob qhia zoo. Qhov system compatibility kuj coj cov txiaj ntsig kev noj qab haus huv tseem ceeb. Cov tsev kho mob tsis tas yuav muab pov tseg cov kev taw qhia uas twb muaj lawm thiab phom biopsy los qhia cov koob tshiab, tiv thaiv kev nqis peev yav dhau los. Tus txheej txheem interface kuj yooj yim rau kev tswj cov khoom muag thiab kev xa khoom. Los ntawm txoj kev cob qhia, cov neeg nyob hauv thiab cov phooj ywg tuaj yeem kawm cov txuj ci tseem ceeb puncture biopsy ntawm cov cuab yeej sib koom ua ke, txo cov kev kawm nyuaj thiab cov nqi kawm.
Hauv kev xaus, txoj kev vam meej ntawm AccuSteel™ thiab Quick{0}}Core tsis yog tsuas yog nyob rau hauv lawv txoj kev ua tiav hauv ib tus neeg thev naus laus zis (xws li cov ntaub ntawv, koob qhia, thiab kev pom), tab sis kuj nyob rau hauv lawv "ecological" tsim lub tswv yim. Los ntawm kev ua raws li cov txheej txheem kho mob uas twb muaj lawm thiab cov cwj pwm ua haujlwm, lawv tau txo qis kev cuam tshuam rau kev siv thev naus laus zis thiab txhim kho kev tsim kho tshiab rau hauv kev kho mob niaj hnub. Qhov no qhia tias kev sib tw ntawm cov cuab yeej siv kho mob yav tom ntej yuav nce ntxiv nyob ntawm lawv lub peev xwm los ua "tus phooj ywg ntawm tus neeg", sib koom ua ke rau hauv thiab txhim kho tag nrho cov kev pabcuam kho mob network, thaum kawg tso cai rau kev vam meej kom muaj txiaj ntsig zoo rau txhua tus kws kho mob thiab cov neeg mob.